Get Last Received Signal Values
- **Returns a list of last received signal values.
The maximum size of the list is the
buffer_size
.**
Arguments Description
signal_path (str): The signal path should be in the format:
BusName::MsgId::SignalName
. buffer_size (int): The maximal buffer size to be set.
Returns
- List[Tuple[int, int]]: List of tuples. Each tuple contains the timestamp of the received signal and its value.
List[Tuple[/timestamp/, /value/]].
Example
Get Last Received Signal Values ${bus_name}::${Msg_Id}::${signal_name} ${buffer_size}
Note
An observer on the signal path should be started beforehand.
If the number of the received values are less than the buffer size the keyword will return only the received values.