Test Features Controller Module
- class mtf.test_features_sim.test_features_controller.TestFeaturesSim
- __init__()
- configure_simulation_controller(conf_param_value: str, config_schema_path: str, start_sim=True)
Configure simulation controller and start the simulations if
start_sim
is True.- Parameters:
conf_param_value – path to config file (env.conf file)
config_schema_path – the path to settings file (settings.json file)
start_sim – False: configure controllers only, without starting simulations. Defaults to True: configure controllers and start simulations.
- Returns:
True if the simulation is configured. False otherwise.
Examples: >>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> tfs_instance.configure_simulation_controller(“path/to/env.conf”, “path/to/settings.json”, start_sim=True)
- deconfigure_simulation_controller()
Deconfigure simulation controller Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> tfs_instance.deconfigure_simulation_controller()
- check_simulations_status(simulations_list, simulations_state: str)
Check simulation status :returns: True if all simulations are in the specified state. False otherwise. Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> tfs_instance.check_simulations_status()
- get_all_simulations_name()
Retrieve all simulation names of ECUs from the CarModelSpecification.json file. :returns: list of simulation names of simulated ECUs. Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> result = tfs_instance.get_all_simulations_name()
- send_diag_message(src: int, tar: int, payload: List) bool
send diag message over can
- Parameters:
src – source
tar – target
payload – payload to be sent (list[int])
- Returns:
True is CAN message was sent else False
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> src = 123 >>> tar = 456 >>> payload = [1, 2, 3, 4, 5] >>> result = tfs_instance.send_diag_message(src, tar, payload)
- configure_frame_buffer_max_size(max_size: int)
Set a maximum size for all frame buffers equal to
max_size
- param max_size:
maximum size
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> max_size = 1000 # Replace with the desired maximum size >>> tfs_instance.configure_frame_buffer_max_size(max_size)
# Set a maximum size for all frame buffers equal to the specified max_size.
- start_message_observer(message_path: str, on_change: bool = True, include_empty_frames: bool = False)
Start a listener to monitor a specific
message_path
, values received of this message could be retrieved when the listener is stopped.- Parameters:
message_path – BusName::msgId
on_change – True to get all received values, else false. Defaults to True.
include_empty_frames – True to include frames with empty payload.
- Returns:
True if message observer is started. False otherwise.
- Example:
>>> result = TestFeaturesSim().start_message_observer("Channel::0x123", True, False)
- stop_message_observer(message_path: str, get_values: bool)
Stop a started listener
message_path
, values received of this message could be retrieved ifget_values
isTrue
.- Parameters:
message_path – BusName::msgId
get_values – True to get retrieved values. False otherwise (get empty list)
- Returns:
list contains (timestamp, payload) pairs
- Examples:
>>> values = TestFeaturesSim().stop_message_observer("Channel::0x123", False)
- check_cyclic_timeout(message_path: str, cycle: int, cycle_deviation: int, timeout: int)
- Check whether a message within
message_path
is cyclic or not for a specifictimeout
with a cycle equal tocycle
and with tolerance equal to
cycle_deviation
on ms.
Note: Make sure a listener was already started for the target message.
- Parameters:
message_path – BusName::MsgId
cycle – cycle of msg from NK
cycle_deviation – tolerance
timeout – delay to check the cyclicity
- Returns:
True if the cycle was respected during the timeout. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> result = tfs_instance.check_cyclic_timeout("Channel::0x123", 200, 20, 1000)
- Check whether a message within
- check_multiple_cyclic_messages_with_timeout(message_path: list[str], cycle: list[int], cycle_deviation: list[int], timeout: int)
- Check whether a message within
message_path
is cyclic or not for a specifictimeout
with a cycle equal tocycle
and with tolerance equal to
cycle_deviation
on ms.
Note: Make sure a listener was already started for the target message.
- Parameters:
message_path – List of strings that contains :BusName::MsgId
cycle – cycle of msg from NK
cycle_deviation – tolerance
timeout – delay to check the cyclicity
- Returns:
True if the cycle was respected during the timeout. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> result = tfs_instance.check_multiple_cyclic_messages_with_timeout(["Channel::0x123"], [200], [20], 1000)
- Check whether a message within
- check_cyclic_repetition(message_path: str, cycle: int, cycle_deviation: int, nbr_repetition: int, check_latest_values: bool = True)
Cyclic Repetition Check
Checks whether a message within
message_path
is cyclic or not for a specificnbr_repetition
with a cycle equal tocycle
and with tolerance equal tocycle_deviation
.Note: Make sure a listener was already started for the target message.
- Parameters:
message_path – BusName::MsgId
cycle – cycle of msg from NK
cycle_deviation – tolerance
nbr_repetition – number of occurrence
check_latest_values – check the last nbr_repetition times messages or check all the time intervals. Defaults to True.
- Returns:
True if the cycle was respected during the timeout. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> result = tfs_instance.check_cyclic_repetition("Channel::0x123", 200, 20, 3)
- check_repetition(message_path: str, is_received: bool)
Check the reception or the non-reception of
message_path
based onis_received
.Note: Make sure a listener was already started for the target message
- Parameters:
message_path – BusName::MsgId
is_received – ${True} to check the message was received else ${False}
- Returns:
True in case of ‘’is_received’’ is True and the message was received or ‘’is_received’’ is False and the message was not received. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> result = tfs_instance.check_repetition("Channel::0x123", True)
- check_reception(message_path: str, is_received: bool)
Check the reception or the non-reception of
message_path
based onis_received
.Note: Make sure a listener was already started for the target message
- Parameters:
message_path – BusName::MsgId
is_received – ${True} to check the message was received else ${False}
- Returns:
True in case of ‘’is_received’’ is True and the message was received or ‘’is_received’’ is False and the message was not received. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> result = tfs_instance.check_reception("Channel::0x123", True)
- check_payload_byte(message_path: str, byte_indexes: List, bytes_values: List, bytes_mask: List, operation: LogicalOperation = LogicalOperation.ALL)
Verify that the bytes with indexes
byte_indexes
inmessage_path
have the valuesbytes_values
usingbytes_mask
.- Parameters:
message_path – BusName::MsgId
byte_indexes – byte indexes
bytes_values – bytes values
bytes_mask – bytes mask Note: The length of
byte_indexes
,bytes_values
andbytes_mask
should be the sameoperation – Defaults to LogicalOperation.ALL.
- Returns:
True if bytes with indexes are verified. False otherwise.
- Examples:
>>> from mtf.enum_types import LogicalOperation >>> tfs_instance = TestFeaturesSim() >>> message_id = "BusName::MsgId" >>> expected_payload = [0, 1, 2, 3, 4, 5, 6, 7] >>> mask = [0x1, 0x2, 0x3, 0x4, 0xF4, 0xF6, 0x05, 0x01] >>> received_payload = [0xFF, 0xFF, 0xFF, 0xFF, 0xFF, 0xFF, 0xFF, 0xFF] >>> offset = LogicalOperation.ALL >>> result = tfs_instance.check_payload_byte(message_id, expected_payload, mask, received_payload, offset)
- clear_message_buffer(message_path: str)
Clear message buffer of
message_path
.- Parameters:
message_path – BusName::MsgId
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> result = tfs_instance.clear_message_buffer("BusName::MsgId")
- start_signal_observer(signal_path: str, on_change: bool = True, is_physical: bool = False)
Start a listener to specific
signal_path
, values received of this signal could be retrieved when the listener is stopped.- Parameters:
signal_path – The signal path. The path must be in this format: Legacy PDU: bus_name::msg_id::signal_name NPDU: ecu_name::npdu_id::signal_name or ecu_name::npdu_name::signal_name
on_change – true if we need to save the different values received. Otherwise, False even if we receive the same value. Defaults to True.
is_physical – Defaults to False.
- Returns:
True if signal observer was started else False
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> tfs_instance.start_signal_observer("bus_name::0x123::signal_name")
- stop_signal_observer(signal_path: str, get_values: bool)
Stop the started listener for
signal_path
. If ‘’get_values’’ parameter is True, the recorded values are returned.- Parameters:
signal_path – The signal path. The path must be in this format: Legacy PDU: bus_name::msg_id::signal_name NPDU: ecu_name::npdu_id::signal_name or ecu_name::npdu_name::signal_name
get_values – True to get all received values, else false
- Returns:
list contains (timestamp, signal value) pairs.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> tfs_instance.stop_signal_observer("BusName::MsgId::SignalName", True)
- checkSignal(signal_path: str, signal_value: int, comparison: ~mtf.libs.mtf_pybinder.CompareOperation = <CompareOperation.EQ: 0>, logical_operation: ~mtf.enum_types.LogicalOperation = LogicalOperation.ALL, mask: int = 18446744073709551615)
compare last received signal value with the expected one
signal_value
.Note: Make sure a listener was already started for the target message
- Parameters:
signal_path – The signal path. The path must be in this format: Legacy PDU: bus_name::msg_id::signal_name NPDU: ecu_name::npdu_id::signal_name or ecu_name::npdu_name::signal_name
signal_value – signal value
comparison – Defaults to CompareOperation.EQ.
logical_operation – Defaults to LogicalOperation.ALL.
mask – Defaults to 0xFFFFFFFFFFFFFFFF.
- Returns:
True if last received value of
signal_path
isCompareOperation
tosignal_value
. False otherwise.
- Examples:
>>> from mtf.enum_types import CompareOperation >>> tfs_instance = TestFeaturesSim() >>> signal_path = "BusName::MsgId::SignalName" >>> expected_value = 5 >>> tolerance = CompareOperation.EQ >>> result = tfs_instance.checkSignal(signal_path, expected_value, tolerance)
- monitor_always_signal(signal_path: str, signal_value: int, timeout: int, comparison: ~mtf.libs.mtf_pybinder.CompareOperation = <CompareOperation.EQ: 0>, mask: int = 18446744073709551615)
Monitor a signal during a timeout and asserts that the signal value is equal to the given value.
- Parameters:
signal_path – The signal path. The path must be in this format: Legacy PDU: bus_name::msg_id::signal_name NPDU: ecu_name::npdu_id::signal_name or ecu_name::npdu_name::signal_name
signal_value – signal value
timeout – period of time defined as parameter on ms.
comparison – Defaults to CompareOperation.EQ.
mask – Defaults to 0xFFFFFFFFFFFFFFFF.
- Returns:
True if the expected value has been received for the given path before the timeout is elapsed. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> from mtf.enum_types import CompareOperation >>> signal_path = "BusName::MsgId::SignalName" >>> signal_value = 5 >>> timeout = 300 >>> comparison = CompareOperation.EQ >>> mask = "0xFFFFFFFFFFFFFFFF" >>> result = tfs_instance.monitor_always_signal(signal_path, signal_value, timeout, comparison, mask)
- monitor_happened_signal(signal_path: str, signal_value: int, timeout: int, comparison: ~mtf.libs.mtf_pybinder.CompareOperation = <CompareOperation.EQ: 0>, mask: int = 18446744073709551615)
Monitor a signal during a timeout.
Note: make sure a listener was already started.
Info: Unlike monitor_always_signal, this function returns once the signal is found, even before the timeout.
- Parameters:
signal_path – The signal path. The path must be in this format: Legacy PDU: bus_name::msg_id::signal_name NPDU: ecu_name::npdu_id::signal_name or ecu_name::npdu_name::signal_name
signal_value – signal_value
timeout – a period of time defined in ms.
comparison – Defaults to CompareOperation.EQ.
mask – Defaults to 0xFFFFFFFFFFFFFFFF.
- Returns:
True if the expected value has been received before the timeout is elapsed. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> signal_path = "BusName::MsgId::SignalName" >>> expected_value = 5 >>> timeout = 500 >>> comparison = CompareOperation.EQ >>> mask = 0xFFFFFFFFFFFFFFFF >>> tfs_instance.start_message_observer(signal_path) >>> result = tfs_instance.monitor_happened_signal(signal_path, expected_value, timeout, comparison, mask) >>> tfs_instance.stop_signal_observer(signal_path, True) >>> assert result == expected_value
- monitor_always_signals_mixed(signals_paths: list[str], types: list[int], signals_value: list[str], timeout: int, comparison: list[int], masks: list[int])
check mixed signals values with monitor always
- Parameters:
signals_paths – List of signal paths. Each signal path must be in BusName::MsgId::SignalName format.
types – List of signal types. 1 for Ethernet (someip or npdu) and 0 for Legacy signals.
signals_value – List of expected values for the signals.
timeout – Timeout in milliseconds for signals monitoring.
comparison – List of comparison operations, where each operation corresponds to a signal.
masks – List of masks to be applied to signals to mask out irrelevant bits. Default is no mask for all signals.
- monitor_happened_signals_mixed(signals_paths: list[str], types: list[int], signals_value: list[str], timeout: int, comparison: list[int], masks: list[int])
check mixed signals values with monitor happened
- Parameters:
signals_paths – List of signal paths. Each signal path must be in BusName::MsgId::SignalName format.
types – List of signal types. 1 for Ethernet (someip or npdu) and 0 for Legacy signals.
signals_value – List of expected values for the signals.
timeout – Timeout in milliseconds for signals monitoring.
comparison – List of comparison operations, where each operation corresponds to a signal.
masks – List of masks to be applied to signals to mask out irrelevant bits. Default is no mask for all signals.
- monitor_always_signals(signals_paths: list[str], signals_values: list[int], timeout: int, masks: list[int], comparison: list[CompareOperation] | list[int])
Monitor signals paths during a timeout and asserts that the signals values is equal to the given values. Timeout is in milliseconds.
- Parameters:
signals_paths – List of signal paths. Each signal path must be in this format: Legacy PDU: bus_name::msg_id::signal_name NPDU: ecu_name::npdu_id::signal_name or ecu_name::npdu_name::signal_name
signals_values – List of expected values for the signals.
timeout – Timeout in milliseconds for signals monitoring.
masks – List of masks to be applied to signals to mask out irrelevant bits.
comparison – List of comparison operations, where each operation corresponds to a signal.
- Returns:
True if received values equals to expected values.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> signal_paths = ["BusName::MsgId::SignalName", "BusName2::MsgId2::SignalName2", "BusName3::MsgId3::SignalName3"] >>> signals_values = [5, 5, 5] >>> timeout = 1000 >>> masks = [0xFFFFFFFFFFFFFFFF, 0xFFFFFFFFFFFFFFFF, 0xFFFFFFFFFFFFFFFF] >>> comparison = [0, 0, 0] >>> result = tfs_instance.monitor_always_signals(signal_paths, signals_values, timeout, masks, comparison)
- monitor_happened_signals(signals_paths: list[str], signals_values: list[int], timeout: int, masks: list[int], comparison: list[CompareOperation] | list[int])
Check if one of received value of each
signal_path
verifies thecomparison
relation with the providedsignal_values
before the timeout elapsedNote: Make sure a listener was already started for each signal_path
- Parameters:
signals_paths – List of signal paths. Each signal path must be in this format: Legacy PDU: bus_name::msg_id::signal_name NPDU: ecu_name::npdu_id::signal_name or ecu_name::npdu_name::signal_name
signals_values – List of expected values for the signals.
timeout – Timeout in milliseconds for signals monitoring.
masks – List of masks to be applied to signals to mask out irrelevant bits.
comparison – List of comparison operations, where each operation corresponds to a signal.
- Returns:
True if, before the timeout expires, received values equals to expected values.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> signal_list = ["BusName::MsgId::SignalName", "BusName2::MsgId2::SignalName2", "BusName3::MsgId3::SignalName3"] >>> expected_values = [10, 10, 10] >>> timeout = 1000 >>> masks = [0xFFFFFFFFFFFFFFFF, 0xFFFFFFFFFFFFFFFF, 0xFFFFFFFFFFFFFFFF] >>> comparison = [0, 0, 0] >>> result = tfs_instance.monitor_happened_signals(signal_list, expected_values, timeout, masks, comparison)
- stop_signals_observers(signals_paths: list[str])
Stop signal observers of each
signal_path
.Note: Make sure a listener was already started for each signal_path
- Parameters:
signals_paths – List of signal paths. Each signal path must be in this format: Legacy PDU: bus_name::msg_id::signal_name NPDU: ecu_name::npdu_id::signal_name or ecu_name::npdu_name::signal_name
- Returns:
True if all observers has been stopped. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> signal_list = ["BusName::MsgId::SignalName", "BusName2::MsgId2::SignalName2", "BusName3::MsgId3::SignalName3"] >>> result = tfs_instance.stop_signals_observers(signal_list)
- clear_signal_buffer(signal_path: str)
Clear the signal buffer of
signal_path
.- Parameters:
signal_path – The signal path. The path must be in this format: Legacy PDU: bus_name::msg_id::signal_name NPDU: ecu_name::npdu_id::signal_name or ecu_name::npdu_name::signal_name
- Returns:
True if signal buffer was cleared. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> signal_path = "BusName::MsgId::SignalName" # Replace with the specific signal path >>> result = tfs_instance.clear_signal_buffer(signal_path)
- get_received_signal_values_timeout(signal_path: str, timeout: int)
Return a list of received values of
signal_path
within the specifiedtimeout
.Note: Make sure a listener was already started for each signal_path.
- Parameters:
signal_path – The signal path. The path must be in this format: Legacy PDU: bus_name::msg_id::signal_name NPDU: ecu_name::npdu_id::signal_name or ecu_name::npdu_name::signal_name
timeout – Timeout in milliseconds
- Returns:
List of (timestamp, value).
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> signal_path = "BusName::MsgId::SignalName" # Replace with the specific signal path >>> timeout = 500 # Replace with the desired timeout in milliseconds >>> received_values = tfs_instance.get_received_signal_values_timeout(signal_path, timeout)
- get_latest_received_signal_values(signal_path: str, buffer_size: int)
Return a list of last
buffer_size
received values ofsignal_path
.Note: Make sure a listener was already started for each signal_path.
- Parameters:
signal_path – The signal path. The path must be in this format: Legacy PDU: bus_name::msg_id::signal_name NPDU: ecu_name::npdu_id::signal_name or ecu_name::npdu_name::signal_name
buffer_size – buffer size
- Returns:
List of (timestamp, value).
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> signal_path = "BusName::MsgId::SignalName" # Replace with the specific signal path >>> buffer_size = 10 # Replace with the desired buffer size >>> latest_values = tfs_instance.get_latest_received_signal_values(signal_path, buffer_size) # Retrieve a list of the last 'buffer_size' received values of signal_path.
- configure_signal_buffer_max_size(max_buffer_size: int)
Set a maximum size for all signals buffers equal to
max_buffer_size
.- Parameters:
max_buffer_size – max buffer size to be set
- Returns:
True if the buffer size was correctly configured.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> max_buffer_size = 1000 # Replace with the desired maximum buffer size >>> result = tfs_instance.configure_signal_buffer_max_size(max_buffer_size) # Set a maximum size for all signals buffers equal to the specified max_buffer_size.
- set_trigger_then_wait_reaction(signals_paths_to_set: list[str], values_to_set: list[str], timeout_to_set: int, signals_paths_to_check: list[str], values_to_check: list[str], timeout_to_check: int, compare_operations: list[int], masks: list[int])
” Set network elements (triggers) over an Ethernet Bus/Legacy Bus. Once all the sets are Valid , the keyword starts checking the reception of the network elements (reaction) over an EthernetBus/LegacyBus/IoChannel . The keyword succeeds if all the triggers Set , and the reactions check conditions are met , Otherwise it fails . TODO: support IOChannels setting
- Parameters:
signals_paths_to_set – List of signals/ethernet paths to set .
values_to_set – List of values to set , could be a value or a couple of (values,update_and_send) like [“1”] or [“1,true”] or [“1,false”] .
timeout_to_set – Maximum accepted delay for the signal to be set on hardware (set is confirmed) in ms.
signals_paths_to_check – List of signals/ethernet/IOChannels paths to check.
values_to_check – List of signals/ethernet/IOChannels values to check.
timeout_to_check – Timeout to monitor the response of the DUT in ms.
compare_operations – List of compare operations between the received values and the values to check (default to equality operations).
masks – applied mask on recieved value to check (default to a list of 0xFFFFFFFFFFFFFFFF).
- Returns:
True if all the sets are confirmed and all the checks are satisfied , Otherwise False.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> tfs_instance.set_trigger_then_wait_reaction([BusName::MessageID::PduName,"EcuName::ServiceID::InstanceID::messageID::MemberName"], ["1,false","2,true"],1500, ["HW::IOChannelName::attributeName","BusName::FrameId::SignalnName"],["10.1,2"],1500,[1,0],[0xFFFFFFFFFFFFFFFF,0xFFFFFFFFFFFFFFFF])
- start_io_channel_observer(signal_path: str, attribute_name: str)
Start a listener to specific io channel, the values received could be retrieved when the listener is stopped.
- Parameters:
signal_path – HW::channel_name
attribute_name – HW type: it could be: {Voltage, Current, DutyCycle only relevant for PWM (yaml field –> MeasurementAttribute: PWM), Frequency, Power : relevant only for PS_Channel}
- Returns:
True if signal observer was started.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> tfs_instance.start_io_channel_observer("HW::channel_name", "Voltage")
- stop_io_channel_observer(signal_path: str, attribute_name: str, get_values: bool)
Stop the started io listener for
signal_path
, values received of this signal could be retrieved ifget_values
is True.- Parameters:
signal_path – HW::HwSignalName
attribute_name – HW type: it could be: {Voltage, Current, DutyCycle only relevant for PWM (yaml field –> MeasurementAttribute: PWM), Frequency, Power : relevant only for PS_Channel}
get_values – True to get retrieved values. False otherwise (get empty list)
- Returns:
True if io signal observer is stopped. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> tfs_instance.stop_io_channel_observer("HW::HwSignalName", True)
- check_io_channel(signal_path: str, attribute_name: str, signal_value: ~numpy.float64, comparison: ~mtf.libs.mtf_pybinder.CompareOperation = <CompareOperation.EQ: 0>, logical_operation: ~mtf.enum_types.LogicalOperation = LogicalOperation.ALL, mask: int = 18446744073709551615)
Check an io signal with specific type
attribute_name
is received as expected or not by making the needed comparison with signal_value.- Parameters:
signal_path – HW::HwSignalName
attribute_name – HW type: it could be: {Voltage, Current, DutyCycle only relevant for PWM (yaml field –> MeasurementAttribute: PWM), Frequency, Power : relevant only for PS_Channel}
signal_value – expected hw value
comparison – Defaults to CompareOperation.EQ.
logical_operation – Defaults to LogicalOperation.ALL.
mask – Defaults to 0xFFFFFFFFFFFFFFFF.
- Returns:
True if the last received value
comparison
to expected valuesignal_value
. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> from mtf.enum_types import CompareOperation, LogicalOperation >>> io_signal_path = "HW::HwSignalName" >>> parameter_name = "Voltage" >>> expected_value = 8.0 >>> compar = CompareOperation.EQ >>> operation = LogicalOperation.ALL >>> result = tfs_instance.check_io_channel(io_signal_path, parameter_name, expected_value, compar, operation)
- monitor_always_io_channel(signal_path: str, attribute_name: str, signal_value: ~numpy.float64, timeout: int, comparison: ~mtf.libs.mtf_pybinder.CompareOperation = <CompareOperation.EQ: 0>, mask: int = 18446744073709551615)
Check all received values for
signal_path
during atimeout
verifies thecomparison
relation with the providedsignal_value
.Note: Make sure a listener was already started for the target io signal
- Parameters:
signal_path – HW::SignalHwName
attribute_name – HW type: it could be: {Voltage, Current, DutyCycle only relevant for PWM (yaml field –> MeasurementAttribute: PWM), Frequency, Power : relevant only for PS_Channel}
signal_value – signal value
timeout – Timeout in milliseconds
comparison – Defaults to CompareOperation.EQ.
mask – Defaults to 0xFFFFFFFFFFFFFFFF.
- Returns:
True if the received value verifies the
comparison
with the expected valuesignal_value
during the timeout. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> from mtf.enum_types import CompareOperation >>> io_signal_path = "HW::SignalHwName" >>> parameter_name = "Voltage" >>> expected_value = 8 >>> timeout = 2000 >>> comparison = CompareOperation.EQ >>> mask = 0xFFFFFFFFFFFFFFFF >>> result = tfs_instance.monitor_always_io_channel(io_signal_path, parameter_name, expected_value, timeout, comparison, mask)
- monitor_happened_io_channel(signal_path: str, attribute_name: str, signal_value: ~numpy.float64, timeout: int, comparison: ~mtf.libs.mtf_pybinder.CompareOperation = <CompareOperation.EQ: 0>, mask: int = 18446744073709551615)
Check if one received value of
signal_path
verifies thecomparison
relation with the providedsignal_value
before the timeout elapsedNote: Make sure a listener was already started for the signal_path
Info: Unlike monitor_always_io_channel, this function returns once the signal value is received, even before the timeout.
- Parameters:
signal_path – HW::SignalHwName
attribute_name – HW type: it could be: {Voltage, Current, DutyCycle only relevant for PWM (yaml field –> MeasurementAttribute: PWM), Frequency, Power : relevant only for PS_Channel}
signal_value – signal value
timeout – Timeout in milliseconds
comparison – Defaults to CompareOperation.EQ.
mask – Defaults to 0xFFFFFFFFFFFFFFFF.
- Returns:
True if before the timeout elapsed, there is a received io value that verifies the expected one. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> io_signal_path = "HW::SignalHwName" >>> parameter_name = "Voltage" >>> expected_value = 11.0 >>> timeout = 2000 >>> result = tfs_instance.monitor_happened_io_channel(io_signal_path, parameter_name, expected_value, timeout)
- clear_io_channel_buffer(signal_path: str, attribute_name: str)
Clear the buffer of
signal_path
.- Parameters:
signal_path – HW::SignalHwName
attribute_name – HW type: it could be: {Voltage, Current, DutyCycle only relevant for PWM (yaml field –> MeasurementAttribute: PWM), Frequency, Power : relevant only for PS_Channel}
- Returns:
True if io channel buffer was cleared. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> signal_path = "HW::SignalHwName" # Replace with the specific signal path >>> attribute_name = "Voltage" # Replace with the attribute name >>> result = tfs_instance.clear_io_channel_buffer(signal_path, attribute_name) # Clear the buffer of the specified signal_path for the given attribute_name.
- monitor_always_io_channels(channels_paths: List[str] | None = None, attributes_names: List[str] | None = None, signal_values: List[float64] | None = None, timeout: int = 0, comparison_signs: List[CompareOperation] | None = None)
Check all received io values for
channels_paths
during atimeout
verifies the comparison relation with the providedsignal_value
Note: Make sure a listener was already started for each channel_path.- Parameters:
channels_paths – List of channels paths. Each one must be in the HW::HwSignalName format.
attributes_names – HW type: it could be: {Voltage, Current, DutyCycle only relevant for PWM (yaml field –> MeasurementAttribute: PWM), Frequency, Power : relevant only for PS_Channel}
signal_values – List of signal values.
timeout – Timeout in milliseconds
comparison_signs – List of comparison sign
- Returns:
True if each channels_path verifies the comparison with its corresponding expected value signal_value during the timeout, Otherwise False.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> io_list = ["HW::HwSignalName", "HW::HwSignalName2"] >>> io_types = ["Voltage", "Voltage"] >>> expected_values = [9.0, 9.0] >>> timeout = 1000 >>> comparison = [2, 2] >>> result = tfs_instance.monitor_always_io_channels(io_list, io_types, expected_values, timeout, comparison)
- monitor_happened_io_channels(channels_paths: List[str] | None = None, attributes_names: List[str] | None = None, signal_values: List[float64] | None = None, timeout: int = 0, comparison_signs: List[CompareOperation] | None = None)
Check if one received io value of
channels_paths
verifies thecomparison_signs
relation with the providedsignal_values
before the timeout elapsedNote: Make sure a listener was already started for each channel_path.
Info: Unlike monitor_always_io_channels, this function returns once the signal values are received, even before the timeout.
- Parameters:
channels_paths – List of channels paths. Each one must be in the HW::HwSignalName format.
attributes_names – HW type: it could be: {Voltage, Current, DutyCycle only relevant for PWM (yaml field –> MeasurementAttribute: PWM), Frequency, Power : relevant only for PS_Channel}
signal_values – List of signal values.
timeout – Timeout in milliseconds.
comparison_signs –
- Returns:
True if each channels_path verifies the comparison with its corresponding expected value signal_value during the timeout, Otherwise False.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> io_signal_path = ["HW::HwSignalName","HW::HwSignalName2"] >>> parameter_name = ["Voltage","Voltage"] >>> expected_value = [11.0, 5.0] >>> timeout = 2000 >>> result = tfs_instance.monitor_happened_io_channels(io_signal_path, parameter_name, expected_value, timeout)
- stop_io_channel_observers(channels_paths: List[str] | None = None, attributes_names: List[str] | None = None)
Stop the started listeners for each channel path.
- Parameters:
channels_paths – List of channels paths. Each one must be in the HW::HwSignalName format.
attributes_names – HW type: it could be: {Voltage, Current, DutyCycle only relevant for PWM (yaml field –> MeasurementAttribute: PWM), Frequency, Power : relevant only for PS_Channel}
- Returns:
True if all the channels_paths are stopped.
Examples: >>> tfs_instance = TestFeaturesSim() >>> io_list = [“HW::HwSignalName”, “HW::HwSignalName2”] >>> io_types = [“Voltage”, “Voltage”] >>> tfs_instance.stop_io_channel_observers(io_list, io_types)
- get_received_io_channel_values_timeout(signal_path: str, attribute_name: str, timeout: int)
Return a list of received io values of
signal_path
within the specifiedtimeout
.Note: A listener on the
signal_path
should be already started.- param signal_path:
HW::SignalHwName
- param attribute_name:
HW type: it could be: {Voltage, Current, DutyCycle only relevant for PWM (yaml field –> MeasurementAttribute: PWM), Frequency, Power : relevant only for PS_Channel}
- param timeout:
Timeout in milliseconds.
- returns:
List of (timestamp, iovalue).
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> signal_path = "HW::SignalHwName" # Replace with the specific signal path >>> attribute_name = "Voltage" # Replace with the attribute name >>> timeout = 1000 # Replace with the desired timeout in milliseconds >>> received_values = tfs_instance.get_received_io_channel_values_timeout(signal_path, attribute_name, timeout)
# Retrieve a list of received io values of signal_path within the specified timeout.
- get_latest_received_io_channel_values(signal_path: str, attribute_name: str, buffer_size: int)
get list of latest
buffer_size
received io signals.Note: A listener on the
signal_path
should be already started.- Parameters:
signal_path – HW::SignalHwName
attribute_name – HW type: it could be: {Voltage, Current, DutyCycle only relevant for PWM (yaml field –> MeasurementAttribute: PWM), Frequency, Power : relevant only for PS_Channel}
buffer_size – buffer size.
- Returns:
List of (timestamp, iovalue).
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> signal_path = "HW::SignalHwName" # Replace with the specific signal path >>> attribute_name = "Voltage" # Replace with the attribute name >>> buffer_size = 10 # Replace with the desired buffer size >>> latest_values = tfs_instance.get_latest_received_io_channel_values(signal_path, attribute_name, buffer_size) # Retrieve a list of the latest 'buffer_size' received io signals for signal_path.
- configure_io_channel_buffer_max_size(max_buffer_size: int)
Set a maximum size for all io channels buffers equal to
max_buffer_size
- Parameters:
max_buffer_size – max buffer size to be set.
- Returns:
True if the buffer size was correctly configured.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> max_buffer_size = 1000 # Replace with the desired maximum buffer size >>> result = tfs_instance.configure_io_channel_buffer_max_size(max_buffer_size) # Set a maximum size for all io channels buffers equal to the specified max_buffer_size.
- set_model_element(model_path: str, param: str)
Execute the method of a specific controller given in model_path by reflection using the list of param given in Parameters.
- Parameters:
model_path – controller name and method name to be invoked separated by :: (e.g. KeyLearningController::PressIdg).
param – list of parameters separated by a comma ‘,’ (e.g. tokenId1,Unlock,500).
- Returns:
True if there is no problem appearing while executing the function. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> model_path = "KeyLearningController::PressIdg" # Replace with the specific controller and method name >>> params = "tokenId1,Unlock,500" # Replace with the list of parameters separated by commas >>> result = tfs_instance.set_model_element(model_path, params) # Execute the method of a specific controller given in model_path by reflection using the provided parameters.
- start_stop_cycle_eth_message(service_path: str, ResumeSending: bool)
start stop the sending of a service interface over ethernet.
- Parameters:
service_path – Path to the Ethernet message for starting or stopping the service.
ResumeSending – True to resume sending the service, False to stop it.
- Returns:
True if the service is stopped (ResumeSending=False) or started (ResumeSending=True), False otherwise.
Sample values for service_path:
ECU_Name::ServiceId::InstanceId (to stop all Someip events or field notifiers given by serviceId). ECU_Name::ServiceId::InstanceId::MessageID (to stop a specific Someip event or field notifier).
Note: MessageID is eventID or fieldID. Examples:
>>> import time >>> tfs_instance = TestFeaturesSim() >>> tfs_instance.start_stop_cycle_eth_message("ECU_Name::0x123::0x1234::0x001", True) >>> time.sleep(5) # Sleep for 5 seconds >>> tfs_instance.start_stop_cycle_eth_message("ECU_Name::0x123::0x1234::0x001", False)
- set_ethernet_network(path: str, param: str)
Set the signal value of a specific member over someip.
- Parameters:
path –
the path of the member to be set separated by :: ( EcuName::ServiceId::InstanceId::MessageId::MemberName
e.g. “X_Y_Z::0x0123::0x0001::0x1:MemberName”).
param – list of parameters separated by a comma ‘,’ (e.g. 1,true)…
- Returns:
True if there is no problem appearing while executing the function. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> path = "X_Y_Z::0x0123::0x0001::0x1::MemberName" # Replace with the specific member path >>> params = "1,true" # Replace with the list of parameters separated by commas >>> result = tfs_instance.set_ethernet_network(path, params) # Set the signal value of a specific member over someip using the provided parameters.
Note: If the SomeIP member to be set belongs to a dynamic array, then the size of the dynamic array should be set previously using this keyword: Prepare SomeIp Dynamic Length Array ${EcuName}::${ServiceId}::${InstanceId}::${MessageId}::${array_member}::1 size
- set_ethernet_networks(paths: List[str], params: List[str])
Set the signal value of a specific members over someip.
- Parameters:
path –
list of several paths of the member to be set separated by :: (e.g. “[X_Y_Z::0x0123::0x0001::0x1::MemberName,
A_B_Z_C::0x0345::0x0002::0x3::MemberName]”).
param – list of several parameters separated by a comma ‘,’ (e.g. “[“1,true”,”2,false”]”)…
- Returns:
True if there is no problem appearing while executing the function. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> paths = "[X_Y_Z::0x0123::0x0001::0x1::MemberName, A_B_Z_C::0x0345::0x0002::0x3::MemberName]" # Replace with the specific member paths >>> params = ["1,true", "2,false"] # Replace with the list of parameters separated by commas >>> result = tfs_instance.set_ethernet_networks(paths, params) # Set the signal value of a specific members over someip using the provided parameters.
Note: If the SomeIP member to be set belongs to a dynamic array, then the size of the dynamic array should be set previously using this keyword: Prepare SomeIp Dynamic Length Array ${EcuName}::${ServiceId}::${InstanceId}::${MessageId}::${array_member}::1 size
- check_ethernet_network(path: str, param: str)
Check the signal value of a specific member over someip.
- Parameters:
path – the path of the member to be checked separated by :: (e.g. “X_Y_Z::0x1013::0x0001::0x1::MemberName”).
param – expected value to be checked.
- Returns:
True if there is no problem appearing while executing the function. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> path = "X_Y_Z::0x1013::0x0001::0x1::MemberName" # Replace with the specific member path >>> expected_value = "true" # Replace with the expected value to be checked >>> result = tfs_instance.check_ethernet_network(path, expected_value) # Check the signal value of a specific member over someip against the expected value.
Note: If the SomeIP member to be checked belongs to a dynamic array, then the size of the dynamic array should be set previously using this keyword: Prepare SomeIp Dynamic Length Array ${EcuName}::${ServiceId}::${InstanceId}::${MessageId}::${array_member}::1 size
- check_ethernet_network_with_mask(path: str, param: str, mask: int, comparison: CompareOperation)
Check the signal value of a specific member over someip.
- Parameters:
path – the path of the member to be checked separated by :: (e.g. “X_Y_Z::0x1013::0x0001::0x1::MemberName”).
param – expected value to be checked.
mask – the mask
comparison – the comparison
- Returns:
True if there is no problem appearing while executing the function. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> path = "X_Y_Z::0x1013::0x0001::0x1::MemberName" # Replace with the specific member path >>> param = "1" >>> comparison = CompareOperation.EQ >>> mask = 0xFFFFFFFFFFFFFFFF >>> result = tfs_instance.check_ethernet_network_with_mask(path, param, mask, comparison) # Check the signal value of a specific member over someip against the expected value.
Note: If the SomeIP member to be checked belongs to a dynamic array, then the size of the dynamic array should be set previously using this keyword: Prepare SomeIp Dynamic Length Array ${EcuName}::${ServiceId}::${InstanceId}::${MessageId}::${array_member}::1 size
- start_ethernet_observer(path: str)
Start ethernet observer : someip and npdu.
- Parameters:
path – the path of the message to be checked separated by :: SOMEIP : ecu_name::service_id::instance_id::message_id NPDU : ecu_name::npdu_id NPDU : ecu_name::npdu_name
- Returns:
True if the observer is started. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> path = "ecu_name::service_id::instance_id::message_id" # Replace with the specific message path >>> result = tfs_instance.start_ethernet_observer(path) # Start the ethernet observer for the specified message path.
- stop_ethernet_observer(path: str)
Stop ethernet observer : someip and npdu.
- Parameters:
path – the path of the message to be checked separated by :: SOMEIP : ecu_name::service_id::instance_id::message_id NPDU : ecu_name::npdu_id NPDU : ecu_name::npdu_name
- Returns:
True if the observer is stopped. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> path = "ecu_name::service_id::instance_id::message_id" # Replace with the specific message path >>> result = tfs_instance.stop_ethernet_observer(path) # Stop the ethernet observer for the specified message path.
- stop_ethernet_observer_and_get_received_values(path: str)
Stop ethernet observer and get collected values: someip and npdu.
- Parameters:
path – the path of the message to be checked separated by :: SOMEIP : ecu_name::service_id::instance_id::message_id NPDU : ecu_name::npdu_id NPDU : ecu_name::npdu_name
- Returns:
List of collected (timestampts,List[int]).
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> path = "ecu_name::service_id::instance_id::message_id" # Replace with the specific message path >>> result = tfs_instance.stop_ethernet_observer_and_get_received_values(path) # Stop the ethernet observer for the specified message path and get the collected values.
- clear_ethernet_buffer(path: str)
Clear ethernet buffer: someip and npdu.
- Parameters:
path – the path of the message to be checked separated by :: SOMEIP : ecu_name::service_id::instance_id::message_id NPDU : ecu_name::npdu_id NPDU : ecu_name::npdu_name
- Returns:
True if the buffer is cleared.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> path = "ecu_name::service_id::instance_id::message_id" # Replace with the specific message path >>> result = tfs_instance.clear_ethernet_buffer(path) # Clear the ethernet buffer for the specified message path.
- check_ethernet_cyclic_repetition(path: str, cycle: int, cycle_deviation: int, nb_repetition: int, check_latest_values: bool = True)
Check ethernet cyclic repetition : someip and npdu.
- Parameters:
path – the path of the message to be checked separated by
cycle – cycle of msg from NK
cycle_deviation – tolerance
nb_repetition – number of occurrence
check_latest_values – check the last repetition_number times messages or check all the time intervals
- Returns:
True if the message respects the required cyclicity. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> path = "ecu_name::service_id::instance_id::message_id" # Replace with the specific message path >>> cycle = 100 # Replace with the cycle of the message from NK >>> cycle_deviation = 5 # Replace with the tolerance >>> nb_repetition = 3 # Replace with the number of required occurrences >>> check_latest_values = True # Set as needed: True to check the last repetition_number times, False for all time intervals >>> result = tfs_instance.check_ethernet_cyclic_repetition(path, cycle, cycle_deviation, nb_repetition, check_latest_values) # Check if the message respects the required cyclicity over someip and npdu.
- check_ethernet_reception(path: str, is_received: bool)
Check ethernet message reception : someip and npdu.
- Parameters:
path – the path of the message to be checked separated by :: (e.g. “ecu_name::service_id::instance_id::message_id”).
is_received – whether the message is received or not
- Returns:
True if message received. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> path = "ecu_name::service_id::instance_id::message_id" # Replace with the specific message path >>> is_received = True # Replace with True if the message is expected to be received, False otherwise >>> result = tfs_instance.check_ethernet_reception(path, is_received) # Check if the ethernet message at the specified path is received based on the provided expectation.
- ethernet_apply_faulty_corrupt_crc(path: str, on_off: bool)
Apply CRC corruption to an Ethernet message. this function aims to disable/enable the CRC calculation, so the user can test sending ethernet payload (SOME/IP or NPDU) with corrupted CRC.
- Parameters:
path – Path to the Ethernet message for which CRC corruption is applied.
on_off – Determines whether to enable (True) or disable (False) CRC corruption.
- Returns:
True if data corrupted when on_off is True and corruption is disabled where on_off is False, else False.
Sample format for
path
:ECU_Name::ServiceId::InstanceId::MethodID (for Someip). ECU_Name::Npdu_Id::Signal_Name (for Npdu). ECU_Name::Npdu_NAme::Signal_Name (for Npdu).
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> ethernet_path = "ECU_Name::ServiceId::InstanceId::MethodID" >>> enable = True >>> tfs_instance.ethernet_apply_faulty_corrupt_crc(ethernet_path, enable)
- ethernet_apply_faulty_corrupt_alive_counter(path: str, on_off: bool)
Apply corruption to the alive counter of an Ethernet message. This function aims to disable/enable the alive counter incrementation, so the user can test sending ethernet payload (SOME/IP or NPDU) with a corrupted Alive counter.
- Parameters:
path – Path to the Ethernet message for which alive counter corruption is applied.
on_off – Determines whether to enable (True) or disable (False) alive counter corruption.
- Returns:
True if faulty applied else False.
Sample format for
path
:ECU_Name::ServiceId::InstanceId::MethodID (for Someip). ECU_Name::Npdu_Id::Signal_Name (for Npdu). ECU_Name::Npdu_Name::Signal_Name (for Npdu).
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> ethernet_path = "ECU_Name::ServiceId::InstanceId::MethodID" >>> enable = True >>> tfs_instance.ethernet_apply_faulty_corrupt_alive_counter(ethernet_path, enable)
- check_list_eth_network(paths: list[str], params: list[str], operation: int)
Check a list of Ethernet network paths.
- Parameters:
paths – list of paths to be checked.
params – list of expected values.
operation – Specifies the operation type.
- Returns:
True if check succeed, false otherwise.
Note
The number of paths to be checked should be equal to the number of params. Sample values for
operation
:0 (All): All the given paths should succeed in order to return true.
1 (ONLY ONE): At least one path should succeed to return true.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> paths = ["ECU::0x123::0x1234::0x1::val1::val2", "ECU::0x100::0x1000::0x1::val1::val3"] >>> params = [1, 0] >>> result = tfs_instance.check_list_eth_network(paths, params, 1)
Note: If the SomeIP member to be checked belongs to a dynamic array, then the size of the dynamic array should be set previously using this keyword: Prepare SomeIp Dynamic Length Array ${EcuName}::${ServiceId}::${InstanceId}::${MessageId}::${array_member}::1 size
- send_someip_raw_payload(path: str, payload: List)
send a raw payload over someip.
- Parameters:
path – the path of the message id(method id/ event id/ notifier id ..) to be set separated by :: (e.g. “ecu_name::service_id::instance_id::message_id”).
payload – payload to be sent.
- Returns:
True if there is no problem appearing while executing the function. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> path = "ecu_name::service_id::instance_id::message_id" # Replace with the specific message id path >>> payload = [0x01, 0x02, 0x03, 0x04] # Replace with the payload to be sent >>> result = tfs_instance.send_someip_raw_payload(path, payload) # Send a raw payload over someip using the provided path and payload.
- start_simulations(ecu_list: List[str])
Start simulations
- Parameters:
ecu_list – list of ecus for simulations to be started.
- Returns:
True if there is no problem appearing while executing the function. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> ecu_list = ["ECU1", "ECU2", "ECU3"] # Replace with the list of ECUs for simulation >>> result = tfs_instance.start_simulations(ecu_list) # Start simulations for the specified list of ECUs.
- stop_simulations(ecu_list: List[str])
Stop simulations.
- Parameters:
ecu_list – list of ecus for simulations to be stopped.
- Returns:
True if there is no problem appearing while executing the function. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> ecu_list = ["ECU1", "ECU2", "ECU3"] # Replace with the list of ECUs for simulation >>> result = tfs_instance.stop_simulations(ecu_list) # stop simulations for the specified list of ECUs.
- resume_simulations(ecu_list: List[str])
Resume simulations.
- Parameters:
ecu_list – list of ecus for simulations to be resumed
- Returns:
True if there is no problem appearing while executing the function. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> ecu_list = ["ECU1", "ECU2", "ECU3"] # Replace with the list of ECUs for simulation >>> result = tfs_instance.resume_simulations(ecu_list) # resume simulations for the specified list of ECUs.
- suspend_simulations(ecu_list: List[str])
Suspend simulations.
- Parameters:
ecu_list – list of ecus for simulations to be suspended
- Returns:
True if there is no problem appearing while executing the function. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> ecu_list = ["ECU1", "ECU2", "ECU3"] # Replace with the list of ECUs for simulation >>> result = tfs_instance.suspend_simulations(ecu_list) # suspend simulations for the specified list of ECUs.
- bus_observer_check_traffic(bus_name: str, timeout: int, event_type: int = 0)
- Check traffic over bus during [ current_time - timeout, current_time]
A listener should be started before over this specific bus and specific event
- Parameters:
bus_name – BusName
timeout – timeout in ms
event_type – enum { 0 : Frame event , 1 : Lin wake up event , 2 : Lin sleep event}
- Returns:
True if there is the event is received during the [ current_time - timeout, current_time], otherwise false.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> bus_name = "bus_name" >>> tfs_instance.bus_observer_check_traffic(bus_name, 1000, 0)
- bus_observer_monitor_traffic(bus_name: str, timeout: int, event_type: int = 0)
Monitor traffic over bus during [ current_time - timeout, current_time]
Note: A listener should be already started over this specific bus.
- Parameters:
bus_name – BusName
timeout – timeout in ms
event_type – enum { 0 : Frame event , 1 : Lin wake up event , 2 : Lin sleep event}
- Returns:
True if there is the event is received during [ current_time - timeout, current_time], otherwise false.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> bus_name = "bus_name" >>> tfs_instance.bus_observer_monitor_traffic(bus_name, 1000,0)
- bus_observer_stop_observer(bus_name: str, event_type: int = 0)
Stop the started observer over specific Bus.
- Parameters:
bus_name – BusName
event_type – enum { 0 : Frame event , 1 : Lin wake up event , 2 : Lin sleep event}
- Returns:
True if the observer is stopped.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> bus_name = "bus_name" >>> tfs_instance.bus_observer_stop_observer(bus_name,0)
- bus_observer_start_observer(bus_name: str, event_type: int = 0)
Start an observer over specific Bus.
- Parameters:
bus_name – BusName
event_type – enum { 0 : Frame event , 1 : Lin wake up event , 2 : Lin sleep event}
- Returns:
True if the observer is started.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> bus_name = "bus_name" >>> tfs_instance.bus_observer_start_observer(bus_name,0)
- subscribe_to_nm_manager(bus_name: str, msg_id: int)
Add message to nm manager of test feature simulation to take into consideration nm state when starting msg.
- Parameters:
bus_name – BusName
msg_id – message id.
- Returns:
True if the message is added.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> bus_name = "BusName" # Replace with the actual bus name >>> msg_id = 123 # Replace with the specific message ID >>> result = tfs_instance.subscribe_to_nm_manager(bus_name, msg_id) # Subscribe a message to nm manager in the test feature simulation.
- start_transmission_frame_sim(bus_name: str, frame_id: int) bool
Start sending a frame using the corresponding simulation.
- Parameters:
bus_name – The bus name over which the sending will be started.
frame_id – The frame identifier.
- Returns:
True if the start was performed.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> bus_name = "BusName" # Replace with the specific bus name >>> frame_id = 123 # Replace with the frame ID to be sent >>> result = tfs_instance.start_transmission_frame_sim(bus_name, frame_id) # Start sending a frame using the corresponding simulation.
- stop_transmission_frame_sim(bus_name: str, frame_id: int) bool
Stop sending a frame using the corresponding simulation.
- Parameters:
bus_name – The bus name over which the sending will be stopped.
frame_id – The frame identifier.
- Returns:
True if the stop was performed.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> bus_name = "BusName" # Replace with the specific bus name >>> frame_id = 123 # Replace with the frame ID to be sent >>> result = tfs_instance.stop_transmission_frame_sim(bus_name, frame_id) # stop sending a frame using the corresponding simulation.
- reset_frame_sim(bus_name: str, frame_id: int) bool
Reset frame using the corresponding simulation.
- Parameters:
bus_name – The bus name over which the sending will be reset.
frame_id – The frame identifier.
- Returns:
True if the reset was performed.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> bus_name = "BusName" # Replace with the specific bus name >>> frame_id = 123 # Replace with the frame ID to be sent >>> result = tfs_instance.reset_frame_sim(bus_name, frame_id) # Reset frame using the corresponding simulation.
- check_monitor_happened_message(message_path, byte_indexes, byte_values, byte_masks, timeout)
- Check monitor happened for message.
This function simply checks if the message with message_path at byte_index got the byte_value at least once during the timeout
- Parameters:
message_path – message path to be listening on.
byte_indexes – list of byte’s indexes to check on.
byte_values – list of byte’s values to be checked.
byte_masks – list of masks.
timeout – timeout
- Returns:
True if the byte_values had been found during timeout.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> message_path = "bus_name::0x123::signal_name" >>> byte_indexs = [0, 1, 2] >>> byte_values = [0x11, 0x22, 0x33] >>> byte_masks = [0xFF, 0xFF, 0xFF] >>> timeout = 1000 >>> result = tfs_instance.check_monitor_happened_message(message_path, byte_indexs, byte_values, byte_masks, timeout)
- monitor_message_is_received(message_path: str, timeout)
Check monitor for received message This function simply checks if the message with message_path was received at least once during the timeout :param message_path: message path to be listening on. :param timeout: timeout :returns: True if the message been received during timeout. Examples: >>> tfs_instance = TestFeaturesSim() >>> message_path = “bus_name::0x123” >>> timeout = 1000 >>> result = tfs_instance.monitor_message_is_received(“bus_name::0x123”, timeout)
- monitor_multi_messages_are_received(message_path: list[str], timeout)
Check monitor for received message This function simply checks if the message with message_path was received at least once during the timeout :param message_path: message path to be listening on. :param timeout: timeout :returns: True if the message been received during timeout. Examples: >>> tfs_instance = TestFeaturesSim() >>> message_path = list of string containing:”bus_name::0x123” >>> timeout = 1000 >>> result = tfs_instance.monitor_message_is_received([“bus_name::0x123”], timeout)
- parse_key_pack_path(key_pack_path: str)
- start_secoc(key_pack_path: str, bit_counting: ~mtf.libs.mtf_pybinder.BitCountingPolicy = <BitCountingPolicy.Sawtooth: 1>)
Start SecOC.
- Parameters:
key_pack_path – key pack path.
bit_counting – bit counting policy (Monotone or Sawtooth)
- Returns:
True if the starting of SecOC has succeeded.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> key_pack_path = "/path/to/key_pack" # Replace with the actual key pack path >>> result = tfs_instance.start_secoc(key_pack_path, BitCounting.Monotone) # Start SecOC using the specified key pack path.
- start_secoc_api(key_pack_path: str, bit_counting: ~mtf.libs.mtf_pybinder.BitCountingPolicy = <BitCountingPolicy.Sawtooth: 1>)
Start SecOC.
- Returns:
True if the starting of SecOC has succeeded.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> result = tfs_instance.start_secoc() # Start SecOC using the specified key pack path.
- set_secoc_bit_counting_policy(bit_counting: ~mtf.libs.mtf_pybinder.BitCountingPolicy = <BitCountingPolicy.Sawtooth: 1>)
set bit counting policy
- Parameters:
bit_counting – bit counting policy (Monotone or Sawtooth)
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> result = tfs_instance.tfs_set_bit_counting_policy(bit_counting)
- enable_secoc()
Enable SecOC
- Returns:
True if secoc is enabled.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> result = tfs_instance.enable_secoc()
- disable_secoc()
Disable SecOC
- Returns:
True if secoc is disabled.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> result = tfs_instance.disable_secoc() # Disable SecOC.
- update_key_pack_secoc(key_pack_path: str, reset_old_keys: bool = False)
Update key pack for SecOC
- Parameters:
key_pack_path – key pack path.
reset_old_keys – if true, the list of keys will be cleaned (erase old keys) and if false, the list of new keys will be added to the old one (if it exists)
- Returns:
True if the key pack is updated.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> key_pack_path = "/path/to/key_pack" # Replace with the actual key pack path >>> result = tfs_instance.start_secoc(key_pack_path)
- enable_faulty_freshness_secoc_all()
Enable faulty freshness for SecOC (for all pdus) Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> tfs_instance.enable_faulty_freshness_secoc_all()
- disable_faulty_freshness_secoc_all()
Disable faulty freshness for SecOC (for all pdus) Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> tfs_instance.disable_faulty_freshness_secoc_all()
- enable_faulty_freshness_secoc(pdu_path: str)
Enable faulty freshness for SecOC (for a specific pdu).
- Parameters:
pdu_path – channel_name::frame_id::pdu_name
- Returns:
True if the faulty freshness is enabled.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> pdu_path = "ChannelName::FrameID::PDUName" # Replace with the specific PDU path >>> result = tfs_instance.enable_faulty_freshness_secoc(pdu_path) # Enable faulty freshness for SecOC for a specific PDU specified by pdu_path.
- disable_faulty_freshness_secoc(pdu_path: str)
Disable faulty freshness for SecOC (for a specific pdu).
- Parameters:
pdu_path – channel_name::frame_id::pdu_name
- Returns:
True if the faulty freshness is disabled.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> result = tfs_instance.disable_faulty_freshness_secoc("channel_name::frame_id::pdu_name")
- overwrite_freshness_counter(value: int)
Overwrite the freshness counter. :param value: the value of the new freshness counter :returns (
bool
): True if the new value of freshness counter has been set successfully. Examples:>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> freshness_value = 100 # Replace with the desired freshness counter value >>> result = tfs_instance.overwrite_freshness_counter(freshness_value) # Overwrite the freshness counter with the specified value.
- start_secoc_by_keys(keys_map: dict[int, list[int]]) bool
add keys and start secoc module Examples :
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> keys_map_sec = {1: [1,2,3,4,5,6,7,8]} >>> result = tfs_instance.start_secoc_by_keys(keys_map_sec)
- add_secoc_keys(keys_map: dict[int, list[int]]) bool
add keys for secoc module. Module should be started before calling this api using start_secoc Or start_secoc_by_keys Examples :
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> keys_map_sec = {1: [1,2,3,4,5,6,7,8]} >>> keys_map_sec_1 = {2: [21,22,23,24,25,26,27,28]} >>> tfs_instance.start_secoc_by_keys(keys_map_sec) >>> result = tfs_instance.add_secoc_keys(keys_map_sec_1)
- add_secoc_freshness_master_config(freshness_pdu_path: str, step: int) bool
Configure freshness master pdu path and its step.Pdu cyclicity should be defined in Databex or overrided using other Apis :param freshness_pdu_path: path of the freshness pdu to simulate :param step: step to increment the pdu passed in the first paramter for each cyclic send Examples :
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> pdu_abs_path_channel = "ChannelName::0x111::PduName" >>> pdu_abs_path_ecuname = "EcuSenderName::0x222" >>> step = 10 >>> result = tfs_instance.add_secoc_freshness_master_config(pdu_abs_path_channel,step) >>> result &= tfs_instance.add_secoc_freshness_master_config(pdu_abs_path_ecuname,step)
- start_stop_secoc_freshness_master(freshness_pdu_path: str, state: bool, chal_resp: bool = True) bool
Start or Stop Sec_oc Freshness Master by specifying the pdu path. :param freshness_pdu_path: path of the freshness pdu to simulate :param state: True will start freshness incrementation and repsond to any freshness challenge :param chal_resp : if true start Response for any Freshness Challenge else no Response will be sent for evry Freshness Challenge :return True if the pdu was found and there is challenge/Response pdus defined in db used to state the application Examples :
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> pdu_abs_path_channel = "ChannelName::0x111::PduName" >>> pdu_abs_path_ecuname = "EcuSenderName::0x222" >>> state_ = True >>> result = tfs_instance.add_secoc_freshness_master_config(pdu_abs_path_channel,state_) >>> result &= tfs_instance.add_secoc_freshness_master_config(pdu_abs_path_ecuname,state_)
- monitor_correctness_secoc(channel_name: str, pdu_name: str, frame_id: int, timeout: int)
Monitor correctness of a specific secured pdu.
- Parameters:
channel_name – the name of the channel
pdu_name – the name of the pdu
frame_id – the id of the frame timeout (int) : a period of time defined in ms
- Returns:
True if all secured data received during this timeout for this specific pdu are correct. Otherwise, False.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> result = tfs_instance.monitor_correctness_secoc("channel_name","pdu_name",0x123,1000)
- check_monitor_always_message(message_path, byte_indexes, byte_values, byte_masks, timeout, operation=LogicalOperation.ALL)
Check monitor Always for message.
This function simply checks if the message with message_path at byte_index got the byte_value during the timeout.
- Parameters:
message_path – message path to be listening on.
byte_indexes – list of byte’s indexes to check on.
byte_values – list of byte’s values to be checked.
byte_masks – list of masks.
timeout – timeout in ms.
operation – Defaults to LogicalOperation.All.
- Returns:
True if the byte_values had been found during timeout.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> message_path = "bus_name::0x123::signal_name" >>> byte_indexs = [0, 1, 2] >>> byte_values = [0x11, 0x22, 0x33] >>> byte_masks = [0xFF, 0xFF, 0xFF] >>> timeout = 1000 >>> result = tfs_instance.check_monitor_always_message(message_path, byte_indexs, byte_values, byte_masks, timeout)
- get_all_protected_frame_by_secoc(channel_name: str) dict[str, set[str]]
Get all secoc frames and correspandiing sender name by bus
- Parameters:
channel_name – the name of the channel
- Returns:
a dict as key the frame_name and as value a set of senders names
- get_someip_last_value(path: str)
Return the last received value for someip.
- Parameters:
path – e.g. Ecu_Name::Service_Id::Instance_Id:Message_Id::Member_Name
- Returns:
the last received value
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> signal_path = "Ecu_Name::Service_Id::Instance_Id:Message_Id::Member_Name" >>> value = tfs_instance.get_someip_last_value(signal_path)
Note: If the SomeIP member to be gotten belongs to a dynamic array, then the size of the dynamic array should be set previously using this keyword: Prepare SomeIp Dynamic Length Array ${EcuName}::${ServiceId}::${InstanceId}::${MessageId}::${array_member}::1 size
- get_npdu_last_value(path: str)
Return the last read npdu value.
- Parameters:
path – path to the desired value, following one of these two formats: 1. EcuName::PduID 2. EcuName::PduID::SignalName 2. EcuName::PduName::SignalName
- Returns:
the last received value
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> result = tfs_instance.get_npdu_last_value("EcuName::PduID")
- monitor_always_eth_network(path: str, expectedValue: str, timeout: int, comparison: int, mask: int)
Monitor Always over ethernet network.
- Parameters:
path – path (e.g. IPF_FAR::0x9004::0x0001::0x8001::statusDrivingReadiness)
expectedValue – expected value.
timeout – timeout in ms.
comparison – EQUAL : 0, >= : 1 , > : 2, <= : 3 , < : 4 , Not EQUAL : 5
mask – mask to be applied to signal.
- Returns:
True if the value from ethernet network is the same as expected. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> network_path = "ECU_Name::Service_Id::Instance_Id::Method_Id" >>> expected_value = "1" >>> timeout = 1000 >>> comparison = 0 >>> mask = 0xFFFFFFFF >>> result = tfs_instance.monitor_always_eth_network(network_path, expected_value, timeout, comparison, mask)
Note: If the SomeIP member to be monitored belongs to a dynamic array, then the size of the dynamic array should be set previously using this keyword: Prepare SomeIp Dynamic Length Array ${EcuName}::${ServiceId}::${InstanceId}::${MessageId}::${array_member}::1 size
- monitor_happened_eth_network(path: str, expectedValue: str, timeout: int, comparison: int, mask: int)
Monitor Happened over ethernet network.
- Parameters:
path – path (e.g. ECU_Name::Service_Id::Instance_Id::Method_Id)
expectedValue – expected value.
timeout – timeout in ms.
comparison – EQUAL : 0, >= : 1 , > : 2, <= : 3 , < : 4 , Not EQUAL : 5
mask – mask to be applied to signal.
- Returns:
True if the value from ethernet network is the same as expected. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> network_path = "ECU_Name::Service_Id::Instance_Id::Method_Id" >>> expected_value = "1" >>> timeout = 1000 >>> comparison = 0 >>> mask = 0xFFFFFFFF >>> result = tfs_instance.monitor_happened_eth_network(network_path, expected_value, timeout, comparison, mask)
Note: If the SomeIP member to be monitored belongs to a dynamic array, then the size of the dynamic array should be set previously using this keyword: Prepare SomeIp Dynamic Length Array ${EcuName}::${ServiceId}::${InstanceId}::${MessageId}::${array_member}::1 size
- monitor_someip_message_reception(path: str, is_recveied: bool, timeout: int)
Monitor someip message reception.
- Parameters:
path – path (e.g. ECU_Name::Service_Id::Instance_Id::Method_Id)
:param is_recveied :param timeout: timeout in ms.
- Returns:
True if a specific someip message was received or not during the timeout passed into paramter. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> network_path = "ECU_Name::Service_Id::Instance_Id::Method_Id" >>> is_recveied = True >>> timeout = 1000 >>> result = tfs_instance.monitor_someip_message_reception(network_path, is_recveied, timeout)
- monitor_ethernet_message_reception(path: str, is_recveied: bool, timeout: int)
Monitor ethernet (Someip and Npdu) message reception.
- Parameters:
path – path (e.g. ECU_Name::Service_Id::Instance_Id::Method_Id)
:param is_recveied :param timeout: timeout in ms.
- Returns:
True if a specific ethernet message was received or not during the timeout passed into paramter. False otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> network_path = "ECU_Name::Service_Id::Instance_Id::Method_Id" >>> is_recveied = True >>> timeout = 1000 >>> result = tfs_instance.monitor_ethernet_message_reception(network_path, is_recveied, timeout)
- get_model_element(model_path: str, param: str)
Execute the method of a specific controller given in model_path by reflection using the list of param given in Parameters.
- Parameters:
model_path – controller name and method name to be invoked separated by :: (e.g. KeyLearningController::SDSKeyDataValidateOrderByBlock). Found in ControllerConfig.json file.
param – list of parameters separated by a comma ‘,’
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> model_path = "KeyLearningController::SDSKeyDataValidateOrderByBlock" # Replace with the desired controller and method name >>> parameters = "param1,param2,param3" # Replace with actual parameters separated by commas found in model file >>> result = tfs_instance.get_model_element(model_path, parameters) # Execute the method specified by model_path with the provided parameters.
- start_ethernet_simulation(ecu_name: str) bool
Start an ethernet simulation by ecu name.
- Parameters:
ecu_name – ecu name.
- Returns:
True if the simulation is started.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> result = tfs_instance.start_ethernet_simulation("ECU")
- stop_ethernet_simulation(ecu_name: str) bool
Stop an ethernet simulation by ecu name.
- Parameters:
ecu_name – ecu name.
- Returns:
True if the simulation is stopped.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> result = tfs_instance.stop_ethernet_simulation("ECU")
- send_npdu_message(ecu_name: str, pdu_id: int, payload: List, force_send: bool = False) bool
Send npdu raw payload message.
- Parameters:
ecu_name – simulation name with respect to loaded database
pdu_id – nPDU id
payload – PDU payload
force_send – if true will send the payload even if no change from last payload, defaults to False
- Returns:
True if payload sent correctly, false otherwise.
- Examples:
>>> tfs_instance = TestFeaturesSim() >>> result = tfs_instance.send_npdu_message("ECU", 0xABC, [0xff,0xff,0xff,0xff,0xff,0xff,0xff,0xff])
- testfeature_cleanuptestcase()
Stop all started observers and listeners. Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> tfs_instance.testfeature_cleanuptestcase() # Stop all started observers and listeners.
- set_reponse_method_timeout(method_path: str, timeout: int)
Sets a response method timeout.
Args:
method_path(str): methodPath should be: Provider_ECU_Name::Service_ID::Instance_Id::Method_ID timeout (int): timeout in ms
Returns :
bool: True if the timeout is set; otherwise, False.
- Examples:
>>> tfs_instance = TestFeaturesSim() # Create an instance of TestFeaturesSim >>> tfs_instance.tfs_set_response_timeout(method_path,timeout)
- control_someip_method_response(method_path: str, method_input_member: str, method_return_member: str, on_off: bool)
Control someip method response . Use this function to control method responses : To enable/disable setting the method response by the value of the method request, provide the ‘method_path’,
‘method_input_member’, and ‘method_return_member’,’on_off’ parameters.
- Args:
- method_path (str): The identifier of the method in the formats :
Provider_ECU_Name::Service_Id::Instance_Id::Method_Id.
method_input_member (str): The input parameter for the method response in the format ‘INPUT::method_input_member’. method_return_member (str): The return parameter for the method response in the format ‘OUTPUT::method_return_member’
on_off (bool): A boolean value indicating whether to stop (False) or resume (True) sending the response based on input and return values.
Examples:
To enable method response control based on input and return values: control_method_response(“Provider_ECU_Name::Service_Id::Instance_Id::Method_Id,INPUT::method_input_member,OUTPUT::method_return_member”, True) control_method_response(“X_Y_Z::0x1013::0x0001::0x1”, “INPUT::ping”, “OUTPUT::pong”, True)
To disable method response control: control_method_response(“Provider_ECU_Name::Service_Id::Instance_Id::Method_Id”, “INPUT::method_input_member”, “OUTPUT::method_return_member” , False) control_method_response(“X_Y_Z::0x1013::0x0001::0x1”, “INPUT::ping”, “OUTPUT::pong”, False)
- start_stop_methode_response(method_path: str, on_off: bool)
stop or resume sending the response automatically for a method, provide the ‘method_path’ and ‘on_off’ parameters. Args:
- method_path (str): The identifier of the method in the formats :
Provider_ECU_Name::Service_Id::Instance_Id::Method_Id.
on_off (bool): A boolean value indicating whether to stop (False) or resume (True) sending the response .
Examples: - To stop sending responses:
control_method_response(“Provider_ECU_Name::Service_Id::Instance_Id::Method_Id”, False) control_method_response(“X_Y_Z::0x1013::0x0001::0x1”, False)
To resume sending responses: control_method_response(“Provider_ECU_Name::Service_Id::Instance_Id::Method_Id”, True) control_method_response(“X_Y_Z::0x1013::0x0001::0x1”, True)
- update_cycle_eth_message(path: str, new_cycle_in_ms: int | None = None) bool
Update cycle the ethernet someip message
- Args:
path (str): The path of the specific Some/IP entity whose cycle the user wants to update new_cycle_in_ms (int): cycle value in ms. This parameter can take 3 values:
0 : SOME/IP entity will be stopped new cycle : SOME/IP entity’s cycle will be updated EMPTY: the original SOME/IP entity cycle configured in the databex will be restored